FA 50N EI SL system
The FA 50N EI SL system curtain wall is a semi-structural façade based on the FA 50N EI system.
The system allows the aesthetics known from the FA 50N SL version to be retained, so that the FA 50N EI SL fire-resistant façade does not visually differ from the non-refractory version of the system.
Advantages of the system
- possibility of maintaining the aesthetics of the façade without any
visible deviation from FA 50N SL system without fire resistance, - the system allows the construction of suspended or filling walls with fire
resistance class EI 60, - the system allows the construction of both flat and broken walls,
- possibility of installing fire protection doors in the façade.
Technical parameters
ENERGY | Thermal insulation EN 10077-2 | Uf = from 1,54 W/m²K |
COMFORT | Acoustic insulation EN ISO 140-3 | Rw = 34 ÷ 53 dB |
Air permeability EN 12207 | AE 1200 | |
Water tightness EN 12208 | RE 1200 | |
SAFETY | Wind load resistance EN 12210 | 1700 Pa |
Anti-theft protection EN 1627 | RC2, RC3, RC4 | |
Impact resistance EN 14019 | I4, E4 | |
Fire resistance | EI 60 |
System characteristic
Minimum visible width (view from inside) | 50 mm |
Minimum visible width (view with outside) | 50 mm |
Minimum mullion depth | 106,3 mm |
Maximum mullion depth | 288,3 mm |
Glazing thickness | 14 ÷ 60 mm |
Glazing method | Glazing with invisible mechanical fixing element and silicone joint |